Salòria Hydraulic Turbines
SALORIA TURBINES TO CHARGING BATTERIES
Salòria Turbines offer an easy solution to obtain electricity by taking advantage of low flow and a medium-high water fall. They are used mainly in isolated areas where electrical energy is needed temporarily or permanently or as a support for other energies (photovoltaic, for example). Turbines intended to charge 12 or 24 V batteries, they are used to charge batteries in chlorination houses, electric shepherds, small isolated huts or wherever a complementary or main energy supply is necessary.
SALORIA TURBINES: DOSSIERS, MANUALS AND TECHNICAL SHEETS
TP-150
TP-150 hydraulic turbine. Pelton turbine perfect for charging 12 or 24Vdc batteries in isolated places. It has a handle and allows its movement and connection very quickly. Ideal for field areas, to charge electric shepherds or similar. Power obtained up to 150W.
Technical data
- Flow rate from 0.3 to 1.0 L / s
- Nominal pressure: 10-60 mca (1-6bar)
- Maximum inlet pressure: 7 bar (about 70mca)
- Voltage output: 12 or 24Vdc
- Maximum production: 150W
- Delivered with connection box (battery charger) and a 3/4″ automated ball valve -Optional-.
Technical data:
- Flow rate from 0.5 to 2.5 L / s
- Nominal pressure: 20-60 mca (2-6bar)
- Maximum input pressure: 9.5 bar (about 95mca)
- Voltage output: 12 or 24 or Vdc (consult for other voltages)
- Maximum production: 550W. According to your needs, models up to 1000W can be made
- Hydraulic connection 1″.
- It is recommended to use it with a Saloria type charge regulator
TF25 MICRO TURBINE SALORIA 12Vdc -25W
Turbine generator: brushless.
To charge a 12V 9-45Ah battery
Hydraulic and electrical conditions:
- ΔP = 1.8 bar Q = 0.95 L/s
- Power supply: 25W -2.2A
- Output voltage: 12Vdc
- Control output: output to control a 2-wire latch solenoid valve
- IP 68
- Nominal pressure: PN10
- Weight: 2.8 Kg
Thread: DN25 -1″ (optional accessories required)
Prices here
The TF25 microturbine itself integrates the electronic regulation card. No charge regulator is required. It integrates an output for a solenoid valve with latch solenoid (2 wires). When the battery is full, the solenoid valve closes automatically.
Ideal for end-of-line areas where electronic instruments (chlorinators, meters, data loggers) need to be powered. It can be installed at the end of a pipe or in a secondary circuit.
- Nominal flow-max (Q) 2.2 -2.5L/s
- Nominal height-max (H) 10-14mca
- Nominal power-max (W) 60 -90W
- Working voltage: 12 or 24Vcc depending on model
- Speed at 10mca 2400 rpm
- Hydraulic connection 1” F (DN25)
- Three-phase generator with 4 poles permanent magnets.
- Electrical winding and rectifier bridge encapsulated with epoxy resin
TF-300
TF-300 hydraulic turbine. Francis type turbine with permanent magnet generator that operates with a flow rate of 2 to 5L/s and for pressure differentials of up to 1 bar (10mca approx). To be installed in parallel to a main pipe equipped with a pressure reducer or shut-off valve or directly to the main pipe. It can be connected tube to tube and no flow is lost. Production up to a maximum of 340W.
Technical data:
- Inline turbine for closed pipes
- Flow rate from 2.0 to 5.0 L / s
- Differential pressure: 1 bar (10 mca approx.)
- Maximum inlet pressure: 8 bar (80 mca approx.)
- Voltage output: 12 or 24Vdc
- Maximum production: 340W
- Hydraulic inlet: 1-1/4″ -outlet 90º with respect to the inlet-
- Rotation: 1600 rpm (at 10 mca)
- Protection: IP 400
- Dimensions: height 380mm (+outlet tube), length 170mm
- Weight: 12kg
TF-600
Francis type TF-600 hydraulic turbine, firm and robust. To charge a battery bank, with permanent magnet generator, offers 24 or 48Vcc (to be chosen when ordering). Works between 3.3 and 7.5L/s with a pressure differential of up to 20mca (2 barx approx). To be installed in parallel with the water pipe, using a pressure reducer or shut-off valve, which provides the pressure differential. Ideal for obtaining electricity in isolated areas, such as supply tanks, chlorination houses, or wherever an electrical source is needed taking advantage of the pipe’s own energy.
Technical data:
- Connection: 1-1/4″ Turbine discharge with respect to the inlet 90 ° (the final part must be immersed in water or returned to the original pipe)
- Flow rate: 3.3-7.5 L/s
- Pressure differential: 20 mca (2 bar approx)
- Maximum operating pressure 6 bar standard 12 on request
- Three-phase permanent magnet alternator *Output voltage: 24 or 48Vcc
- External rectifier bridge
- Revolutions: 1600 rpm approx. at 10 mca (pressure differential), or 2000rpm at 20 mca
- Protection degree IP 44
- Total height 320 mm
- Width 170 mm
- Weight: 12 Kg (without pipe).
TF-750
Francis type hydraulic turbine TF-750, firm and robust, provides up to 750W. To charge a battery bank, with permanent magnet generator, offers 24 or 48Vcc (to be chosen when ordering). Works between 2.7 and 7.7L/s with a pressure differential of up to 20mca (2 bar approx). To be installed in parallel to the water pipe, using a pressure reducer or shut-off valve, which provides the pressure differential. Ideal for obtaining electricity in isolated areas, such as supply tanks, chlorination houses, or wherever an electrical source is needed taking advantage of the pipe’s own energy.
Technical data:
- Connection: 1-1/4″ Turbine discharge with respect to the inlet 90 ° (the final part must be immersed in water or returned to the original pipe)
- Flow rate: 3.3-7.5 L/s
- Pressure differential: 20 mca (2 bar approx)
- Maximum operating pressure 6 bar standard 12 on request
- Three-phase permanent magnet alternator *Output voltage: 24 or 48Vcc
- External rectifier bridge
- Revolutions: 1600 rpm approx. at 10 mca (pressure differential), or 2000rpm at 20 mca
- Protection degree IP 44
- Total height 320 mm
- Width 170 mm
- Weight: 12 Kg (without pipe).